Temperature accuracy, resolution and operating range

Read the conditions attached to accuracy, update rate, response time and assembled-device ratings

Updated 11 November 2026

Temperature sensor specifications answer different questions. Keep the conditions next to each value when comparing devices: a finer data increment does not, by itself, establish a smaller measurement error.

ParameterMeaningDocumented example
ResolutionHow finely the data can be represented.Temperature/humidity sensor: 0.1°C temperature resolution.
Accuracy and conditionsThe error specification under stated conditions.The same sensor: ±0.5°C at 25°C.
Operating rangeThe specified environment for the assembled device.Digital temperature sensor: -40°C to +80°C.
Update and responseUpdate interval and response to environmental change.Temperature/humidity updates: 1 s; temperature response: ≤15 s at 1 m/s airflow.

Swipe horizontally to read the full table

Check the temperature range for the stated accuracy

The digital temperature sensor has an assembled-device operating range of -40°C to +80°C. Its ±0.5°C accuracy is specified over 0°C to +70°C. Record those conditions separately instead of extending that accuracy across the entire operating range.

Use the assembled-device rating

The same source lists a theoretical chip range of -55°C to +125°C. That is not the assembled-device rating. Use the stated complete-device range when selecting the product, including the probe and construction conditions.

Match the measurement to the task

A one-second update interval does not mean the sensor completes its response to every change in one second. State the actual temperature range, changes to identify, acceptable error and receiving device/software. Then compare measurement, supply, output and integration conditions together.